Skip to main content
Authorized Fortinet reseller · DynaScale Technologies888-907-0723 · 24/7[email protected]
FGR-SERIES

FortiGate Rugged Series

Fanless, extended-temperature FortiGate for OT, industrial and outdoor sites

Environment
Extended temperature, fanless
Mounting
DIN rail / wall
Power
DC input

The FortiGate Rugged range runs the same FortiOS in a hardened enclosure: fanless, extended operating temperature, DIN-rail or wall mount, and DC power input. Current models include the FGR-60F and FGR-70F. They are built for substations, factory floors, wellheads, roadside cabinets and vehicles, places where a standard desktop appliance fails on heat, dust or vibration long before it runs out of throughput.

Is this the right model?

Where it fits, and where it stops fitting

Environment decides the model here, not performance. Confirm operating temperature range, mounting method, ingress protection and power input first; those constraints eliminate most of the catalogue before throughput is worth discussing. Substation and rail deployments frequently require IEC 61850-3 or IEEE 1613 compliance; tell us the standard you are held to and it determines the model outright. Because these sites are expensive to visit, the cellular options and the central-management story matter more than the numbers: most rugged estates are large, remote, identical, and managed through FortiManager templates from day one.

Highlights

  • Fanless and extended-temperature, no moving parts to fail
  • DIN rail mounting and DC power for industrial cabinets
  • Industrial protocol signatures for Modbus, DNP3 and IEC 61850
  • Same FortiOS, so it fits the estate you already manage

Typical deployments

  • Electrical substations and utility infrastructure
  • Factory floor and process control networks
  • Roadside cabinets, wellheads and vehicle deployments
Buying guidance

What to work out first

FortiGate Rugged models run the same FortiOS in a hardened enclosure: fanless, extended operating temperature, DIN-rail or wall mount, and DC power input. They are built for substations, factory floors, wellheads, roadside cabinets and vehicles, places where a standard desktop appliance fails on heat, dust or vibration rather than on throughput.

The security case is specific to OT. Rugged models carry FortiGuard's industrial signature set covering Modbus, DNP3, IEC 61850 and similar protocols, which lets you write policy against industrial traffic instead of treating the whole OT segment as one opaque zone.

Because these are placed where a truck roll is expensive, the cellular variants and the management story matter more than the raw numbers. Most rugged deployments are managed centrally through FortiManager from day one.

Questions worth answering before you order

What is the actual environment?

Confirm operating temperature range, mounting method, ingress protection and power input before anything else. These constraints eliminate most of the catalogue before throughput is even discussed.

Do you need certified compliance?

Substation and rail deployments often require IEC 61850-3 or IEEE 1613 compliance. Tell us the standard you are being held to; it determines the model, not the preference.

How does it get its uplink?

Many rugged sites are cellular-only. Confirm whether you need integrated LTE/5G, dual-SIM, or an external FortiExtender.

Who manages it after install?

Rugged estates are usually large, remote and identical. That is exactly the case for FortiManager templates and, if you would rather not staff it, DynaScale's managed firewall service.

Specifications

What this includes

Fortinet publishes no throughput table for this product; it is licensed per user, endpoint, workload or account. What follows is capability and sizing, not benchmarks.

Environmental

Environmental
CoolingFanless, no moving parts to fail in dust or vibration
MountingDIN rail or wall mount
Power inputDC
Intended environmentIndustrial, outdoor, vehicular and OT deployments

Security

Security
FortiOSThe same operating system and feature set as every other FortiGate
OT protocol supportFortiGuard industrial signatures covering Modbus, DNP3, IEC 61850 and similar
ManagementFortiManager templates, the normal choice for large, remote, identical estates

Current models

Current models
FGR-60FCompact rugged appliance for cabinets and small OT cells
FGR-70FHigher port count for larger industrial segments

Why no throughput figures here

Fortinet does not include the rugged models in the Product Matrix that the rest of this catalog is transcribed from, and rugged specifications vary meaningfully by hardware revision, regional SKU and certification variant. Rather than publish a number we cannot cite, which is the one thing this catalog does not do; we will send you the current data sheet for the exact variant that suits your environment, the same working day you ask.

Why no throughput figures here
Throughput figuresProvided on request against the specific variant, not published here unverified
CertificationsConfirmed against your requirement (e.g. IEC 61850-3, IEEE 1613)

Sources

Reproduced from Fortinet published documentation and subject to change without notice. Where a figure is load-bearing for your design, ask us to confirm it in writing before you order; we will.

Buyers also compare